Blockage of leachate drainage facilities is a common engineering problem in landfill operation. The key factors that cause blockage of drainage facilities in landfill leachate are the deposition of suspended solids (SS) with colloids and the precipitation of inorganic salts. To determine the combined sedimentation law of SS, colloids and inorganic salts, a combined sedimentation test of suspended solids, colloids and inorganic salts was conducted. To further clarify the resulting clogging characteristics of the water-conducting sand layers, a sand column blocking test were conducted, and miner...