Visualized strain/stress sensing is receiving interests in structural health monitoring area, but former approaches cannot be effectively applied to civil infrastructure monitoring, because of limited sensitivity to low-level response and/or limited response to civil structures for both static and dynamic strain/stress. This paper presents a high-sensitivity and low-cost method to visualize the strain by employing the precisely controllable Wheatstone bridge and monochrome electroluminance (EL) technology. A sensor prototype is developed to convert the structural strain responses into visible ...