In accordance with the BS7448,fracture toughness test standard,CTOD(crack tip open displacement) fracture toughness tests were conducted for the heavy plate E43 at room temperature 20℃.The CTOD values of the base metal,heat effect zone and welded seam were obtained.The results show that their CTOD values are more than the allowable values,the str...